STRUCTURAL FEATURES
• Compressor: Hermetic scroll type compressor with thermal protection and sump heater.
• High efficiency at partial loads with 3 capacity control
• Evaporator: Polyurethane insulated stainless steel plate evaporator with differential pressure switch and internal frost protection heater.
• Condenser: Condenser with copper pipes / aluminum fins.
• Fan: External rotor equipped with internal thermal protection and protection grilles.
• Control: Microprocessor control with Adaptive Function Plus.
• Structure: Galvanized and powder polyester paint coated structure.
STANDARD FEATURES
•Circuit breaker switches for fan and compressor.
•High and low pressure indicator.
•Master / slave control of up to parallel connected 4 units.
•Clock board
VERSIONS
B -Standard version, cooling only (TCAEBY)
T - High efficiency version, cooling only (TCAETY) – heat pump unit (THAETY)
S - Silent version, cooling only (TCAESY) – heat pump unit (THAESY)
Q - Super silent version cooling only (TCAEQY) – heat pump unit(THAEQY)
FACTORY FITTED ACCESSORIES
• Shell&tube evaporator
• Single or double pump. 1 master and 1 spare aplication in double pump options
• Standard/high pressure versions of pumps are optional.
• TANK AND PUMP UNIT: Expansion tank, manual air discharge valve, with safety valve and water side pressure indicator 230-440 depending on model storage tank up to liter. Low and high pressure versions of the pumps are available.
• Variable Primary Flow (VPF) control.
• Desuperheater
• 100% heat regain option.
• FI-10 kit: Ability to work down to -10ºC outdoor tempreature (Standard on S versions).
• FI-15 kit: Ability to work down to -15ºC outdoor tempreature (With EC fans)
• Condensation control with high pressure fans (only B and T versions).
• Power factor correction capacitor (Cos?>0,94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameters measurement device
• Energy efficiency optimization.
• Soft starter.
• Noise insulation.
• Compressor noise insulator
• Cooling circuit suction and discharge valves.
• Refrigerant leak detector.
• Refrigerant circuit high and low pressure indicators.
• Double safety valves.
• Metal filters or battery protection grids.
• Copper / copper or copper / aluminum pre-painted aluminum batteries.
• Minimum / maximum power supply control.
• Digital input for double set point.
• Setpoint shift (4-20 mA analog signal).
• Evaporator heater, electrical panel, storage tank for frost protection, electric pumps and heat exchangers for heat regain, if available.
• Storage tank heater option.
• Low temperature water production
• Interfaces for serial communication with other devices.
• Rubber vibrators.