WinPOWER EXP 360-650 kW Scroll

Energy Saving Special Solutions in Commercial Buildings and Residences
TER (Total efficiency coefficient) value up to 7.9
Class A Polyvalent device
ncreased outside air operating limits

igh Energy Efficiency and Comfort in All Seasons
Devices designed for 2, 4 and 6 pipe systems
Wide and Smart Options

 

STRUCTURAL FEATURES


•  Compressor: Hermetic scroll type compressor with thermal protection, oil sump heater.
•  High efficiency in partial loads with 4-6 capacity control.
•  Evaporator: Stainless steel polyurethane insulated plate evaporator with differential pressure switch and internal victaulic connection.
•  Condenser: Copper tube / aluminum finned condenser.
•  Fan: Axial fan with internal thermal protection and protection grid For T version; EC fans are standard in Q version).
•  Control: Microprocessor control with Adaptive Function Plus.
•  Structure: Galvanized and polyester powder paint coated steel structure.


STANDARD FEATURES


• Fan and compressor circuit breaker switches, anti-freeze heater for heat exchanger.
• High and low pressure indicator.
• Electronic expansion valve.
• Clock board.


VERSIONS


T - Y&High efficient version, EXPsystems unit (TXAETY)
- Super silent verison, EXPsystems unit (TXAEQY)


FACTORY FITTED ACCESSORIES


• Shell & tube evaporators.
• Single or double pump. 1 master and 1 spare aplication in double pump options. Standard / high pressure versions of the pumps are optional.
• TANK and PUMP UNIT: Storage tank up to 700- 1000 liters, depending on the model, with expansion tank, manual air discharge valve, safety valve and water side pressure gauge. Pumps available in low and high pressure versions.
• Desuperheater.
• FI-15 kit: Ability to work down to -15ºC outdoor tempreature (Condensation control) (With EC motor fans).Standard on Q version.
• Condensation control with high pressure fans (only in T versions)
• Power factor correction capacitor (Cos ??> 0.94)
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameters measuring device.
• Energy efficiency optimization.
• Soft starter.
• Soundproofed compressor box and cooling circuit sound insulation.
• Compressor noise insulator.
• Cooling circuit suction and discharge valves
• Refrigerant leak detector.
• Refrigerant circuit high and low pressure indicators.
• Double safety valves.
• Metal filters or battery protection grids.
• Lower compartment protection grids.
• Copper tube / coated aluminum fins or coils with copper tubes / copper fins.
• Digital input for double set point.
• Setpoint shift (4-20 mA analog signal)
• Evaporator heater for frost protection, electrical panel, storage tank, electric pumps and heat exchangers for heat recovery, if available.
• Interfaces for serial communication with other devices.
• Spring vibration absorbers.


Last Update 26.01.2021 16:49:02