WinPOWER SE 335-861 kW Scroll

With R410a Gas Compact and High Efficiency Series
4- 5- 6 stage capacity control
Easy to install with Tank & Pump accessories
2-pipe + heat regain (RC100) option
Internal Master / Spare Control

Eurovent Certified High Performance
High Energy Efficiency & Comfort in All Seasons
Wide and Smart Options
Increased outdoor operating limits
Energy Saving Special Solutions in Commercial Buildings and Residences

 

STRUCTURAL FEATURES


• Compressor: Hermetic scrolltype compressor with thermal protection, oil sump heater.
• High efficiency in partial capacities with 4-5-6 capacity control.
 Evaporator: Stainless steel polyurethane insulated plate evaporator with differential pressure switch and internal victaulic connection.
 Condenser: Micro channels (TCAEY) or copper tube / aluminum fin condenser
• Fan:  Axial fan with internal thermal protection and protection grid.
• Control: Microprocessor control with Adaptive Function Plus.
 Structure: Galvanized and powder polyester paint coated steel structure.

STANDARD FEATURES


•Fan and compressor circuit breaker switches.
•High / low pressure indicator.
•Master / slave control of up to parallel connected 4 units.
•Clock board.

VERSIONS


• B - Standard version, cooling only (TCAEBY) – heat pump unit (THAEBY)
• S - Silent version, cooling only(TCAESY) – heat pump unit (THAESY)


FACTORY FITTED ACCESSORIES


• Shell&tube evaporator,
• Single or double pump. 1 master and 1 spare aplication in double pump options. Standard / high pressure versions of the pumps are optional.
• TANK and PUMP UNIT: Storage tank up to 700- 1000 liters, depending on the model, with expansion tank, manual air discharge valve, safety valve and water side pressure gauge. The pumps are available in low and high pressure versions.
• Variable Primary Flow (VPF) control.
• Desuperheater.
• % 100 heat regain option.
• FFI-10 kit: Ability to work down to -10ºC outdoor tempreature (Condensation control)(Standard on S versions).
• FI-15 kit: Ability to work down to -15ºC outdoor tempreature (Condensation control) (With EC motor fans).
• Condensation control with high pressure fans.
• Power factor correction capacitor (Cos?> 0.94).
• Forced limit of power consumption.
• Forced noise limit.
• Energy parameters measuring device.
• Energy efficiency optimization.
• Soft starter.
• Noiseproofed compressor box or compressor box and cooling circuit noise insulation (THAEY)
• Compressor noise insulator.
• Cooling circuit suction and discharge valve.
• Refrigerant leak detector.
• Refrigerant circuit high and low pressure indicators.
• Double safety valves.
• Digital input for double set point
• Metal filters (THAEY) or condenser battery protection grids.
• Epoxy coated micro-channels condenser (TCAEY).
• Copper / copper or copper / coated aluminum condenser (THAEY).
• Minimum / maximum power supply control.
• Setpoint shift (4-20 mA analog signal).
• Evaporator heater for frost protection, electrical panel, storage tank, electric pumps and heat exchangers for heat recovery, if available.
• Low temperature water production.
• Interfaces for serial communication with other devices.
• Vibration receivers.


Last Update 26.01.2021 10:23:30